CS210*E-GMX-1SS
- Overview
- Specifications
- Drawings
- Pictures


The CS210*E-GMX-1SS offers very high cooling power for fast cool downs and low base temperatures. This system is ideal when characterizing large materials with High Heat loads or when the lowest possible temperature wants to be achieved.
This system is capable of achieving vacuum levels of 10-7 Torr with an appropriate vacuum system. The lower vacuum reduces the sample surface contamination such as water molecules, which can be particularly detrimental to IR spectroscopy.
The nickel plated copper radiation shield provides a durable low emissivity finish, ideal for reducing radiant heat load in low temperature experiments.
The CS210*E-GMX-1SS is powered by our DE-210 series closed cycle cryocoolers. These liquid helium free cryostats use a pneumatically driven Gifford-McMahon Cycle to extract heat from the system.
Applications
- Optical
- Electro-Optical
- Raman
- UV, Vis, IR
- FTIR
- Electroluminescence
- Photoluminescence
- Resistivity
- Hall Probe Experiments
- Diamond Anvil Cell
- Deep-Level Transient Spectroscopy (DLTS)
- Thermal, Electrical and Magnetic Susceptibility
- Magneto Optical Kerr Effect (MOKE)
Features
- Cryogen Free
- All Stainless Steel Construction
- Large Clear view optical windows (1.25in)
- Large sample viewing angle for optical collection (F/1.6)
- Fully Customizable
Typical Configuration
- Cold head (DE-210AE)
- Compressor (ARS-10HW)
- Bolt on instrumentation skirt
- 2 Helium hoses
- Stainless steel vacuum shroud with 4 window ports for optical and electrical experiments (GMX-1SS)
- Nickel plated copper radiation shield
- 2 High purity quartz windows
- Instrumentation for temperature measurement and control:
- 10 pin hermetic feedthrough
- 50 ohm thermofoil heater
- Silicon diode sensor curve matched to (± 0.5 K) for control
- Calibrated silicon diode sensor (±12 mK) with 4 in. free length for accurate for sample measurement
- Wiring for electrical experiments:
- 10 pin feedthrough
- 4 copper wires
- Sample holder for optical and electrical experiments
- Temperature controller
Options and Upgrades
- 4 K Cold head (0.8 W @ 4.2 K)
- Turbo upgrade for faster cooldown times
- 450 K High temperature interface
- 800 K High temperature interface
- Custom temperature sensor configuration (please contact our sales staff)
- Custom wiring configurations (please contact our sales staff)
- Window material upgrades (custom materials available)
- Sample holder upgrades (custom sample holders available)
The ARS Advantage
Our high temperature interfaces use a unique combination of mechanical and thermodynamic properties to create a high temperature thermal disconnect between the cold head and the sample space. This allows for heating of the sample space far in excess of the maximum 355K temperature of our cryocoolers.
450K The easy way
Our 450K interface is a simple semi-perminant addition to the cold tip that expands the upper sample temperature range by 95K utilizing most of the same instrumentation as our standard cryocoolers.
800 K Pouring on the Heat
Our specially design 800K interface goes beyond the standard techniques to provide a unique system that maximizes thermal conduction at low temperatures while minimizing heat transfer at high temperatures. Beyond the safe operating temperature of Silicon Diodes the standard sensors are replaced with E-type Thermocouples and Platinum RTDs.

From our standard offerings of single strand copper and low noise coaxial wiring packages, to any number of custom wiring configurations, our technicians painstakingly wrap each cold head for optimum thermal anchoring.
Typical instrumentation for temperature measurement and control include, one 50 ohm thermofoil heater, one curve matched silicon diode for rough temperature control, and one free length calibrated diode for direct attachment to the sample or sample holder for accurate temperature measurement. Silicon diode sensors are favored heavily for most standard applications, because of their low cost, durability, and stability, but we do offer a wide variety of other sensors for different applications such as Cernox sensors for high magnetic fields, E-type thermocouples for 4 K - 800 K measurements, and Platinum RTD's for accurate high temperature measurements.
Our wide selection of wiring and instrumentation is matched by an equally wide selection of temperature controllers from Cryocon, Lakeshore, and Scientific Instruments.

Window Materials for all Transmission Ranges
High purity quartz is the standard window material for most of our optical cryostats, but we have a wide variety of other window materials available, from near IR materials like CaF2 and KBr, to far IR and terrahertz like Ultra High Molecular Wright Polyethylene and Picarin, to Kapton, Mylar and Beryllium for X-ray experiments. If you don't see the window material you're looking for please contact one of our sales representatives.
Optimized for Weak Signal Collection with Minimum Heat Load
The tiered optical access of the 1.25" clear view vacuum shroud window and radiation shield optical ports allows for a large cone of optical access (F/1.6) and at the same time limited the area of exposure to 300K thermal radiation.
Low Stress Window Mounts
Our window ports are designed to gently cradle the window material creating a low stress seal that limits optical distortions

Whether the measurement is optical or electrical in nature, the sample large or small, we have a sample holder for almost any measurement. The CS210*E-GMX-1SS can accept all but our largest sample holders. As will all of our cold fingers the DE-210 has a 1/4-28 threaded hole on the cold tip to mount the sample holder. So even if you do not find what you need from our wide variety of sample holders there is always the option of attaching a custom sample holder.

The water cooled ARS-10HW compressor that powers the DE-210 Series Cold heads has many benefits that are amplified in small laboratory settings. The water cooling redirects heat energy that would otherwise be dumped into the lab, by a large cooling fan. The lack of a large cooling fan also dramatically reduces the noise of these compressors (only 60 dBA). Additionaly with minimum air circulation, the air currents and dust are kept to a minimum. The high efficiency heat exchanger results in low water usage, and saves space inside the compressor giving it a small footprint. When water is not available our Coolpac™ remote recirculation system can send cooling water from up to 100ft away.

The ARS DE-210 Closed Cycle Cryocooler operates on a pneumatically driven Gifford-McMahon refrigeration cycle that is both mechanically simple and robust.
12,000 Maintenance cycle
Over time the internal components of the cold head begin to wear. Eventually the performance of the cold head will decline and sometime after 12,000 hours certain internal components need to be replaced or refurbished. With Most Closed cycle cryocoolers the only option is to send the cold head back to the manufacturer for service.
A Second Option
The Simplicity of the ARS pneumatically driven cryocooler allows for another option. Our customers have the option of purchasing a service kit for our 10K and 5.5K cryocoolers that replaces all of the worn components. This service kit can be ordered ahead of time and reduce down time to a matter of hours instead of weeks.
GMX-1SS Specifications
| Cooling Technology- | ||
|---|---|---|
| DE-210 | Closed Cycle Cryocooler |
|
| Refrigeration Type | Pneumatically Driven Gifford-McMahon Cycle | |
| Liquid Cryogen Usage | None, Cryogen Free | |
| Temperature*- | ||
| DE-202AF | < 9 K - 350 K | |
| DE-202SF | < 3 K - 350 K | |
| With 800 K Interface | (Base Temp + 2 K) - 800 K | |
| With 450 K Interface | (Base Temp + 2 K) - 450 K | |
| Stability | 0.1 K | |
| *Based on bare cold head with a closed radiation shield, and no additional sources of experimental or parasitic heat load. | ||
| Sample space- | ||
| Diameter | 79 mm (3.1 in) | |
| Height | 49 mm (1.9 in) | |
| Sample Holder Attachment | 1/4-28 screw | |
| Sample Holder | View our Sample Holder Collection | |
| Optical Access- | ||
| Window Ports | 4 - 90° Apart | |
| Diameter | 41 mm (1.63 in) | |
| clear view | 32 mm (1.25 in) | |
| #/F | 1.6 | |
| Window Material | View our Wide Selection of Window Materials | |
| Temperature Instrumentation and Control (Standard)- | ||
| Heater | 1 - 50ohm Thermofoil Heater Anchored on Cold Tip | |
| Control Sensor | 1 - Curve Matched Silicon Diode | |
| Sample Sensor | 1 - Calibrated Silicon Diode. | |
| Custom Instrumentation | Contact ARS for available Options | |
| Instrumentation Access- | ||
| Instrumentation Skirt | Bolt-on, Stainless | |
| Pump out Port | 1 - NW-25 | |
| Instrumentation Ports | 3 | |
| Instrumentation Wiring | Contact our sales staff for wiring options | |
| Vacuum Shroud- | ||
| Material | Stainless Steel | |
| Length | 508 mm (20 in) | |
| Diameter | 160 mm (6.3) (at the sample space) | |
| Width | 160 mm (6.3 in) (at the sample space) | |
| Radiation Shield- | ||
| Material | Nickel Plated Copper | |
| Attachment | Threaded | |
| Optical Access | 0, 2, or 4(customer specified) | |
| Cryostat Footprint- | ||
| Overall Length | 784 mm (30.84 in) | |
| Motor Housing Diameter | 156 mm (6.14 in) | |
| Rotational clearance | Consult Factory for Options | |
Cryocooler Specifications
| Cryocooler Model | DE-210AE | DE-210SE | |||
|---|---|---|---|---|---|
| Frequency | 60 Hz | 50 Hz | 60 Hz | 50 Hz | |
| Base Temperature | < 9 K | < 9 K | < 3 K | < 3 K | |
| Cooling Capacity- | 4.2 K | - | - | 0.8 W | 0.8 W |
| 10 K | 4 W | 4 W | 9 W | 9 W | |
| 20 K | 17 W | 17 W | 16 W | 16 W | |
| 77 K | 25 W | 25 W | 25 W | 26 W | |
| Radiation Shield Cooling Capacity | 60 W | 60 W | 60 W | 60 W | |
| (1st Stage Cooling Capacity at 77K) | |||||
| Maximum Cylinder Temperature | 355 K | 355 K | |||
| Cooldown Time- | 20K | 35 min | 35 min | 40 min | 40 min |
| Base Temperature | 70 min | 70 min | 80 min | 80 min | |
| Weight | Expander | 14 kg (31 lbs) | 15 kg (33 lbs) | ||
| Compressor Model | ARS-10HW | ARS-10HW | |||
| Standard Voltage | Min | 208 V | 190 V | 208 V | 190 V |
| Max | 230 V | 2210 V | 230 V | 210 V | |
| Power Usage | Three Phase | 7.7 kW | 7.7 kW | 7.7 kW | 7.7 kW |
| Dimensions: | L | 483 mm (19 in) | 483 mm (19 in) | ||
| W | 534 mm (21.0 in) | 534 mm (21.0 in) | |||
| H | 618 mm (24.3 in) | 618 mm (24.3 in) | |||
| Weight | Compressor | 113 kg (250 lbs) | 113 kg (250 lbs) | ||
| Typical Maintenance Cycle | 12,000 hours | 12,000 hours | |||
CS210*E-GMX-1SS
High Performance Closed Cycle Cryostat
for Optical and Electrical Experiments
ARS-10HW
Water Cooled Compressor
Click on the Images for full size