DE-204 Cold Head Specifications

Cryocooler Model DE-204AE DE-204A(T)E DE-204PE DE-204SE
  Frequency 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz
Base Temperature < 9 K < 9 K < 9 K < 9 K < 5.5 K < 5.5 K < 4 K < 4 K
Cooling Capacity 4.2 K - - - - - - 0.2 W 0.16 W
  10 K 2 W 1.6 W 2.7 W 2.2 W 3 W 2.4 W 4 W 3.2 W
  20 K 9 W 7.2 W 12 W 9.6 W 8 W 6.4 W 8 W 6.4 W
  77 K 17 W 14 W 23 W 18.4 W 14 W 11 W 14 W 11 W
Radiation Shield Cooling Capacity 18 W 14 W 24 W 19 W 18 W 14 W 18 W 14 W
(1st Stage Cooling Capacity at 77 K)                
Maximum Cylinder Temperature 355 K 355 K 355 K 355 K
Cooldown Time 20K 30 min 36 min 25 min 30 min 40 min 48 min 40 min 48 min
  Base Temperature 60 min 72 min 50 min 60 min 90 min 96 min 90 min 108 min
Weight Expander 7.7 kg (17 lbs) 7.7 kg (16 lbs) 7.7 kg (16 lbs) 7.1 kg (16 lbs)

ARS-4HW Compressor Specfications


Compressor Model ARS-4HW
  Frequency 60 Hz 50 Hz
Standard Voltage Min 208 V 190 V
  Max 230 V 210 V
Transformer Options 10%   220 V, 230 V
  15%   240 V
Power Usage Singe Phase 3.6 kW 3.0 kW
Refrigerant Gas 99.999% helium gas,
pre-charged
Noise Level 60 dBA
Ambient Temperature 12 - 40 C (54-104 F)
Cooling Water Consumption 1.5 L / min (0.4 Gal. / min)
  Temperature 10 - 35 C (50-95 F)
  Connection 3/8 in. Swagelok fitting
Dimensions L 483 mm (19 in)
  W 434 mm (17.1 in)
  H 516 mm (20.3 in)
Weight Compressor 72 kg (160 lbs)
Typical Maintenance Cycle 30,000 hours
Water Recirculation Option CoolPac compatible